Analisa Meningkatnya Rugi-Rugi Daya Akibat Jatuh Tegangan Pada Proses Transmisi 150 KV Maligi-Indoliberty

Authors

  • M Haikal Ismawan Program Studi Teknik Elektro Universitas Singaperbangsa Karawang
  • Dian Budhi Santoso Program Studi Teknik Elektro Universitas Singaperbangsa Karawang

DOI:

https://doi.org/10.30736/je-unisla.v6i2.690

Keywords:

Electrical energy, Transmission, Voltage drop, Power loss

Abstract

 Tariffs are one of the driving forces of the economy, so electrical energy providers should be more effective in presenting electrical energy so that the basic electricity tariffs can be cheaper, one way is to reduce power losses in the transmission process. power losses arise because the transmission conductor has resistance values, power losses can increase if the voltage in the transmission system decreases, in the case study taken at PT PLN (Persero) UPT Karawang Gardu Induk (GI) 150 KV maligi the direction of the conductor Indoliberty 150 KV transmission when the average load in one day is 18.85 MW and 10.01 MVAr there is a power loss of 7065.05 W in one day when the voltage is 150 KV, and power losses increase by 411.17 W when there is a
voltage drop of 2.8766% from a voltage of 150 KV to 145.82 KV which increases the cost loss of Rp. 9838,396 per day.

Downloads

Download data is not yet available.

References

Abdullah, D., & Badaruddin, B. (2020). Analisa Perbaikan Penampang Penghantar Guna Mengurangi Drop Tegangan dan Simulasi Etap 16.0 Pada JTR GD KRDB di Wilayah Kerja PT. PLN (Persero) ULP Serang Kota.

Daniel Dalam, H. (2013). Analisis Susut Energi Pada Sistem Jaringan Distribusi Di Pt. Pln Apj Yogyakarta Upj Wonosari

Unit Semanu. Seminar Nasional Informatika Yogyakarta, 2013(semnasIF), 1979–2328.

Gaol, D. S. L., Firdaus. (2017). Estimasi Rugi Rugi Energi Pada Sistem Distribusi Radial 20 Kv Dengan Metode Loss Factor. Jom FTEKNIK, 4(2), 1–6.

Hariyadi, S. (2017). Analisis Rugi-Rugi Daya Dan Jatuh Tegangan Pada Saluran Transmisi Tegangan Tinggi 150 Kv Pada Gardu Induk Palur – Masaran. Universitas Muhammadiyah Surakarta, 1, 20.

Hayadi, A. (2013). Analisis Rugi-Rugi Energi Sistem Distribusi. 1–6.

Kartoni, J., Ervianto, E. (2016). Analisa Rekonfigurasi Pembebanan Untuk Mengurangi Rugi-Rugi Daya Pada Saluran Distribusi 20 Kv. Jom FTEKNIK, 3(2), 1.

Mardhatillah, M. F., & Ervianto, E. (2017). Analisa Rugi-rugi Daya Feeder Lobak Pada Jaringan PT . PLN ( Persero ) Area Pekanbaru. Jom FTEKNIK, 4(2), 1–10.

Nopianto, A. S. (2016). Perhitungan Jatuh Tegangan Dan Susut Daya Serta Upaya Perbaikan Penyaluran Daya Listrik Pada PT. PLN (Persero) Rayon Sambas. Untan, 2, No 1.

S, D. A., & Ervianto, E. (2016). Dengan Pendekatan Kurva Beban Pada Jaringan Distribusi Pt . Pln ( Persero ) Area Pekanbaru. Jurnal Teknik Elektro, 3(2), 1–6.

Shidiq, M. (2010). Penurunan Jatuh Tegangan Dan Rugi Daya. Jurnal EECCIS, IV(1), 35–38.

Syaputra, A., & Ervianto, E. (2017). Perhitungan Rugi Daya Saluran Distribusi Primer 20 kV Feeder Adi Sucipto di GI Garuda Sakti Dengan Metode Ladder Iterative Technique. Jom FTEKNIK, 4(1), 1–10.

PlumX Metrics

Published

20-09-2021

How to Cite

Ismawan, M. H., & Santoso, D. B. (2021). Analisa Meningkatnya Rugi-Rugi Daya Akibat Jatuh Tegangan Pada Proses Transmisi 150 KV Maligi-Indoliberty. JE-Unisla, 6(2), 14–18. https://doi.org/10.30736/je-unisla.v6i2.690

Issue

Section

editorial elektro

Most read articles by the same author(s)