Abstract

Study of the stability of the power system as an important and complex problem in the operation of a power system that is safe from the power system when there are small or large disruptions in the connected power system. This discussion studies load flow and stability analysis while a multi-machine power system with ETAP software.Single diagram system multi-engine system 9-bus system configured in ETAP. For  each multi-machine power system power flow and power flow analysis have been provided a complete tool in ETAP.The results of the load flow data are presented for each case. For the transient stability analysis, the system is simulated with three phase disturbance to earth and single phase interference in ETAP. The combination of AVR, Governor, and PSS maintains synchronization during all types of errors. Variations in rotor angle, bus voltage, and engine speed were studied in each case study. Simulation results are shown through graphical analysis. In the ETAP simulation study explains that the application of PSS can substantially improve the transient stability of the power system.

Downloads

Download data is not yet available.

References

ETAP manual, ETAP AUTOMATION PVT. LTD. INDIA, Available in Dept. EE, RCCIIT, APJ Abdul Kalam Innovation Center, RCCIIT R&D Cell.

ETAP Power station user guide, User-Defined Dynamic Model, chapter 20.

C.L.Wadha, Electrical Power System, New Age International Pub. pp. 230-245, 2003.

J.B. Gupta, A Course in Electrical Power System, S.K. Kataria & Sons; 2013 edition PP. 875-910, 2013

P. W. Sauer and M. A. Pai, Power System Dynamics and Stability, Prentice Hall. Inc,1998.

P. Kundur, Power System Stability & Control‖, Mc Graw Hill ,Inc, 1994.

F. Selwa and L. Djamel, “Transient Stability Analysis of Synchronous Generators in Electrical Network,†International Journal of Scientific & Engineering Research, vol. 5, no.8, August 2014.

P. Kundur , M. Klein, G. J Rogers and M. S Zywno, “Application of Power System Stabilizer for Enhancement of overall System Stability,†IEEE Trans. On Power system vol.4, no.2 , pp. 614-626, May 1989.

J. S. Patel and M. N. Sinha, “Power System Transient Stability Analysis Using ETAP Software,†National conference on recent Trends in Engineering and Technology, May2011

Cekdin Cekmas, 2006, â€Sistem Tenaga Listrikâ€, Penerbit Andi, Yogyakarta

PlumX Metrics

Published

08-04-2020

How to Cite

Budi Laksono, A., & Abidin, Z. (2020). Analisis Aliran Daya dan Stabilitas Sistem Tenaga Listrik Sistem Multi Mesin dengan ETAP. JE-Unisla, 5(1), 297–302. https://doi.org/10.30736/je.v5i1.423

Issue

Section

editorial elektro